RM Analyzer Help

Action > SupAndXLc

Adding of the (factorized) result values of a Load Case with variable sign. The appropriate sign to achieve unfavorable results is taken.  The result vector is not superimposed if the characteristic value is exactly zero.

SettingDescription
Action Code of the selected Action. It is possible to switch to another action without leaving and re-entering the input function.
Action will be skipped (Option) The action will be skipped in the calculation process if the option is selected.
Input-1 > Superposition file Name of the treated superposition file where the result values are added.
Input-2 > Load case name Name of the Load Case to be added (selection in the pulldown-menu)
Input-3 > (Factor 1) Multiplication factor for the added Load Case results

Default: 1.0

Output 1 > (Superposition file) Name of a new superposition file, if the original file must not be overwritten
Note: Any specified existing superposition file will be overwritten without notice.
Delta-T Duration of the Action (not applicable for this action)
Description Descriptive text for the selected Action (max. 80 characters)